Emergency repair on a 120KW ABB ACS800 drive
Number of project hours: 18 hours
2 technicians
Client expectation
Our client, a leader in the manufacturing of polyethylene films, called us following two breakdowns encountered on two 120 KVA ABB ACS800 drives. Indeed, when the first one broke down at 8.00 pm, our client had immediately installed the drive they had in stock, but at 10.00 pm, that also broke down.
DV GROUP Solution
Our Technical Assistance team immediately sent an expert on site. The diagnosis revealed the failure of an IGBT module characterised by a short circuit between an output phase and the DC bus. The breakdown was identical on both drives. In order to allow our client to restart as quickly as possible, we dismantled the drive on site and brought both defective products back to the workshop in order to carry out an emergency repair.
Work carried out
- Full disassembly of the drive
- Replacement of the IGBT module from DV GROUP stock
- Repair of the IGD card
- Preventive maintenance of the product (upgrading of the electronic cards, replacement of the turbine bearings, cleaning)
- Load test
Our experts worked all night in order to refurbish one of the drives, so our client was able to restart his production line at 8.00 am that morning.
The drive taken from stock was also repaired over the next two days.
Clients gains and benefits
- Speed: emergency diagnosis and repair in order to be able to restart within a few hours
- Savings: low cost compared to replacing with new
- Expertise: efficiency of our Technical Assistance team and intervention by a DV GROUP electronics expert in the middle of the night
Expertise
We provide you with engineering, maintenance and control solutions based on our knowledge of your processes.
Case studies
You may also be interested in
Vibration monitoring of a coffee production line
Obsolescence Management: Audit of a Truck Engine Factory’s Equipment Fleet
Repair and reliability of drives
ELOPAK: Corrective preventive electronic maintenance
Preventive maintenance of Siemens Masterdrives
43 Simovert Masterdrive drives from 0.75 kW to 700 kW
To safeguard the reliability of 32 Siemens (6SE70) Masterdrives on a paper machine section
MELEGHY: Preventive maintenance of 24 Siemens Powerblocks drives
Preventive maintenance contract
2 LEROY SOMER 600 kW variators
Overhaul of 12 Siemens Torque Simotics T-1FW3 motors
Preventive maintenance for 17 Siemens servomotors and drives
X-FAB : Replacement of two extractor fans
Troubleshooting of an induced draught fan
19 50 kg (2.2 kW) to 5 ton (7.2MW) motor/reducer/ventilator assemblies
Overhaul of an extruder reducer with 2 indexed output shafts
Maintenance électronique et électromécanique de 3 installations Banbury (moteurs CC et variateurs)
Moteur Siemens 450 KW avec mode de refroidissement à eau
Révision d’un moteur CC 540 KW de laminoir
LENGLET IMPRIMEURS : 1€ to reduce your energy bill
Modelling of the HTA/BT electric network
Fiabilisation d’une ligne de décapage
EMC analysis
Modélisation réseau
Reducer polymerizer vibration monitoring
Maintenance method improvement project
Contrat de mesures vibratoires
Contrat de suivi vibratoire
Contrôle par onde de choc de 46 moteurs asynchrones de 7,5KW (400V) à 750KW (5000V)
Remplacement de 4 CN obsolètes 810T par 1 CN Sinumerik 840D sl Siemens
Modification îlot ZF
Remplacement robot presse
Cellule robotisée de dépose résine et convoyage d’une ligne d’emballage de batteries DAIMLER
Robot de palettisation ligne peinture
Robot de lavage de bacs à endives
Digital Twin d’une nouvelle ligne de production
LENGLET IMPRIMEURS : Retrofit variateurs moteurs unités de récupération de solvant
Rétrofit de l’électronique de puissance et de commande d’une ligne de découpe
Rétrofit électrique pont HFX 16T
Motorisation of compressors in a colliery gas compression station
Obsolescence of the oven’s 7 CC ALSTHOM drives
Retrofitting of an impressive balancing bench
Retrofit of a machine for superfinishing machined parts
Retrofitting of the robotics part of a nine-colour printing line