Emergency repair on a 120KW ABB ACS800 drive
Client expectation
Our client, a leader in the manufacturing of polyethylene films, called us following two breakdowns encountered on two 120 KVA ABB ACS800 drives. Indeed, when the first one broke down at 8.00 pm, our client had immediately installed the drive they had in stock, but at 10.00 pm, that also broke down.
DV GROUP Solution
Our Technical Assistance team immediately sent an expert on site. The diagnosis revealed the failure of an IGBT module characterised by a short circuit between an output phase and the DC bus. The breakdown was identical on both drives. In order to allow our client to restart as quickly as possible, we dismantled the drive on site and brought both defective products back to the workshop in order to carry out an emergency repair.
Work carried out
- Full disassembly of the drive
- Replacement of the IGBT module from DV GROUP stock
- Repair of the IGD card
- Preventive maintenance of the product (upgrading of the electronic cards, replacement of the turbine bearings, cleaning)
- Load test
Our experts worked all night in order to refurbish one of the drives, so our client was able to restart his production line at 8.00 am that morning.
The drive taken from stock was also repaired over the next two days.
Competenza
Vi forniamo soluzioni di ingegneria, manutenzione e controllo basate sulla nostra conoscenza dei vostri processi.
Casi di studio
Potreste essere interessati anche a

Repair and reliability of drives

ELOPAK: Corrective preventive electronic maintenance

Preventive maintenance of Siemens Masterdrives

43 Simovert Masterdrive drives from 0.75 kW to 700 kW

To safeguard the reliability of 32 Siemens (6SE70) Masterdrives on a paper machine section

MELEGHY: Preventive maintenance of 24 Siemens Powerblocks drives

Preventive maintenance contract

2 LEROY SOMER 600 kW variators

Overhaul of 12 Siemens Torque Simotics T-1FW3 motors

Preventive maintenance for 17 Siemens servomotors and drives

X-FAB : Replacement of two extractor fans

Troubleshooting of an induced draught fan

19 50 kg (2.2 kW) to 5 ton (7.2MW) motor/reducer/ventilator assemblies

Overhaul of an extruder reducer with 2 indexed output shafts

LENGLET IMPRIMEURS : 1€ to reduce your energy bill

Modelling of the HTA/BT electric network

Motorisation of compressors in a colliery gas compression station

Obsolescence of the oven’s 7 CC ALSTHOM drives

Retrofitting of an impressive balancing bench

Retrofit of a machine for superfinishing machined parts

Retrofitting of the robotics part of a nine-colour printing line