To safeguard the reliability of 32 Siemens (6SE70) Masterdrives on a paper machine section
Number of project hours : 28 hrs
Technicians : 2
Client expectation
The DV GROUP team travelled to Austria for a paper-manufacturing client specialising in packaging and corrugated cardboard. The company called on our expertise to safeguard the reliability of the VAC Drive and Siemens Masterdrives (55 kW – 400 kW) section during their production shutdown. The technicians faced several constraints:
- The condition of the drives was unknown
- The equipment was obsolete
- There was a significant breakdown rate
- And production is only stopped for only two days a year.
DV GROUP Solution
For this type of intervention, a service including the disassembly of the products is usually carried out, but the geographical distance and factory stoppage time made this solution impossible. In addition, the analysis of the situation did not allow a precise current MTBF (Mean Time Between Failures) of the section to be obtained, so it was difficult to determine the measures necessary to suit the client’s budget and return on maximum investment.
DV GROUP offered a step-by-step solution:
- Diagnosis of the onsite products:
- Definition of the urgent measures to be carried out to significantly increase the MTBF
- Definition of the pertinent preventive measures to obtain maximum ROI within the client’s budget
- Decontamination of the section
- Program safeguarding
- Refurbishing of the cooling circuit, integrating an exchange of the turbines
Word carried out
The DV GROUP team safeguarded the reliability of the section within the allotted two days. Following their analysis, the technicians realised that three variators were presenting faults: the condition of the PCB IVI, IGB and PSU was very impaired. Remedial work was carried out in keeping with the preventive steps.
![](https://dv-group.com/app/uploads/2023/09/FBZ1832-002.jpg)
Clients gains and benefits
-
A recommendation for a second phase adapted to the client’s budget constraints
-
Improved ROI
-
Increase in MTBF
-
Increase in machine availability
-
Alert to new risks to be taken into account
-
Prioritisation of measures to be carried out
-
An operation appropriate to the client’s budget constraints
Expertise
We provide you with engineering, maintenance and control solutions based on our knowledge of your processes.
Case studies
You may also be interested in
![](https://dv-group.com/app/uploads/2024/04/AdobeStock_637482892-scaled.jpeg)
Vibration monitoring of a coffee production line
![](https://dv-group.com/app/uploads/2023/11/AdobeStock_116573127-scaled.jpeg)
Obsolescence Management: Audit of a Truck Engine Factory’s Equipment Fleet
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_462080587-scaled.jpeg)
Repair and reliability of drives
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_154900643-scaled.jpeg)
ELOPAK: Corrective preventive electronic maintenance
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_433333796-scaled.jpeg)
Preventive maintenance of Siemens Masterdrives
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_165501360-scaled.jpeg)
43 Simovert Masterdrive drives from 0.75 kW to 700 kW
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_237714206-scaled.jpeg)
MELEGHY: Preventive maintenance of 24 Siemens Powerblocks drives
![](https://dv-group.com/app/uploads/2023/09/semi-conducteur-.jpeg)
Preventive maintenance contract
![](https://dv-group.com/app/uploads/2023/09/PLASTURGIE-shutterstock_135780191-scaled.jpg)
Emergency repair on a 120KW ABB ACS800 drive
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_368270998-scaled.jpeg)
2 LEROY SOMER 600 kW variators
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_100684673.jpeg)
Overhaul of 12 Siemens Torque Simotics T-1FW3 motors
![](https://dv-group.com/app/uploads/2023/09/Sans-titre.jpg)
Preventive maintenance for 17 Siemens servomotors and drives
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_363566054-scaled.jpeg)
X-FAB : Replacement of two extractor fans
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_241373299-scaled.jpeg)
Troubleshooting of an induced draught fan
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_250184718-scaled.jpeg)
19 50 kg (2.2 kW) to 5 ton (7.2MW) motor/reducer/ventilator assemblies
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_462080587-scaled.jpeg)
Overhaul of an extruder reducer with 2 indexed output shafts
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_405468105-scaled.jpeg)
Maintenance électronique et électromécanique de 3 installations Banbury (moteurs CC et variateurs)
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_462080587-scaled.jpeg)
Moteur Siemens 450 KW avec mode de refroidissement à eau
![](https://dv-group.com/app/uploads/2023/09/SIDERURGIE-shutterstock_676446463-scaled.jpg)
Révision d’un moteur CC 540 KW de laminoir
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_238930922-scaled.jpeg)
LENGLET IMPRIMEURS : 1€ to reduce your energy bill
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_583316652.png)
Modelling of the HTA/BT electric network
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_105213795-scaled.jpeg)
Fiabilisation d’une ligne de décapage
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_568665983-scaled.jpeg)
EMC analysis
![](https://dv-group.com/app/uploads/2023/09/AdobeStock_568665983-scaled.jpeg)
Modélisation réseau
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_402052651-scaled.jpeg)
Reducer polymerizer vibration monitoring
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_233258281-scaled.jpeg)
Maintenance method improvement project
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_464890100-scaled.jpeg)
Contrat de mesures vibratoires
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_583316652.png)
Contrat de suivi vibratoire
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_616267004-scaled.jpeg)
Contrôle par onde de choc de 46 moteurs asynchrones de 7,5KW (400V) à 750KW (5000V)
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_182646517-scaled.jpeg)
Remplacement de 4 CN obsolètes 810T par 1 CN Sinumerik 840D sl Siemens
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_354562959-3-scaled.jpeg)
Modification îlot ZF
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_551291603-scaled.jpeg)
Remplacement robot presse
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_577951445-scaled.jpeg)
Cellule robotisée de dépose résine et convoyage d’une ligne d’emballage de batteries DAIMLER
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_144907982-scaled.jpeg)
Robot de palettisation ligne peinture
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_126082864-scaled.jpeg)
Robot de lavage de bacs à endives
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_38521068-scaled.jpeg)
Digital Twin d’une nouvelle ligne de production
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_238930922-scaled.jpeg)
LENGLET IMPRIMEURS : Retrofit variateurs moteurs unités de récupération de solvant
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_551291603-scaled.jpeg)
Rétrofit de l’électronique de puissance et de commande d’une ligne de découpe
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_70388297-2-scaled.jpeg)
Rétrofit électrique pont HFX 16T
![](https://dv-group.com/app/uploads/2023/08/IMG_4071.jpg)
Motorisation of compressors in a colliery gas compression station
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_484497686-scaled.jpeg)
Obsolescence of the oven’s 7 CC ALSTHOM drives
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_604772398-scaled.jpeg)
Retrofitting of an impressive balancing bench
![](https://dv-group.com/app/uploads/2023/08/image-retouchee-SKF-scaled.jpg)
Retrofit of a machine for superfinishing machined parts
![](https://dv-group.com/app/uploads/2023/08/AdobeStock_238930922-scaled.jpeg)
Retrofitting of the robotics part of a nine-colour printing line
![](https://dv-group.com/app/uploads/2023/08/asterix-e1693211335813.jpg)