Troubleshooting of an induced draught fan
Number of hours dedicated to the project: 65 hours
Client expectation
Our client is a waste reclamation and processing centre. They contacted us following an outbreak of fire on a bearing of the 450 kW electric cooling fan, causing a site shutdown.
DV GROUP Solution
Emergency intervention by the Electro-mechanical teams that same night.
When our experts arrived onsite, it appeared that the bearing had welded itself to the shaft. The decision was therefore made to displace the bearing housing in order to be able to carry out an emergency repair. Three teams from Cambrai and Grigny were required day and night in order to complete the work.
The client restarted production the next evening.
In order to secure production, we put in place continuous machine feedback.
Work carried out
- Machine monitoring using a Phantom captor for feedback following the work
- Replacement of bearing housings, onsite modification of the chassis in order to displace the housing fixing
Clients gains and benefits
- Restarting of production within a few hours: reduction of stoppage time
- Machine feedback in order to anticipate any faults
Expertise
We provide you with engineering, maintenance and control solutions based on our knowledge of your processes.
Case studies
You may also be interested in

Vibration monitoring of a coffee production line

Obsolescence Management: Audit of a Truck Engine Factory’s Equipment Fleet

Repair and reliability of drives

ELOPAK: Corrective preventive electronic maintenance

Preventive maintenance of Siemens Masterdrives

43 Simovert Masterdrive drives from 0.75 kW to 700 kW

To safeguard the reliability of 32 Siemens (6SE70) Masterdrives on a paper machine section

MELEGHY: Preventive maintenance of 24 Siemens Powerblocks drives

Preventive maintenance contract

Emergency repair on a 120KW ABB ACS800 drive

2 LEROY SOMER 600 kW variators

Overhaul of 12 Siemens Torque Simotics T-1FW3 motors

Preventive maintenance for 17 Siemens servomotors and drives

X-FAB : Replacement of two extractor fans

19 50 kg (2.2 kW) to 5 ton (7.2MW) motor/reducer/ventilator assemblies

Overhaul of an extruder reducer with 2 indexed output shafts

Maintenance électronique et électromécanique de 3 installations Banbury (moteurs CC et variateurs)

Moteur Siemens 450 KW avec mode de refroidissement à eau

Révision d’un moteur CC 540 KW de laminoir

LENGLET IMPRIMEURS : 1€ to reduce your energy bill

Modelling of the HTA/BT electric network

Fiabilisation d’une ligne de décapage

EMC analysis

Modélisation réseau

Reducer polymerizer vibration monitoring

Maintenance method improvement project

Contrat de mesures vibratoires

Contrat de suivi vibratoire

Contrôle par onde de choc de 46 moteurs asynchrones de 7,5KW (400V) à 750KW (5000V)

Remplacement de 4 CN obsolètes 810T par 1 CN Sinumerik 840D sl Siemens

Modification îlot ZF

Remplacement robot presse

Cellule robotisée de dépose résine et convoyage d’une ligne d’emballage de batteries DAIMLER

Robot de palettisation ligne peinture

Robot de lavage de bacs à endives

Digital Twin d’une nouvelle ligne de production

LENGLET IMPRIMEURS : Retrofit variateurs moteurs unités de récupération de solvant

Rétrofit de l’électronique de puissance et de commande d’une ligne de découpe

Rétrofit électrique pont HFX 16T

Motorisation of compressors in a colliery gas compression station

Obsolescence of the oven’s 7 CC ALSTHOM drives

Retrofitting of an impressive balancing bench

Retrofit of a machine for superfinishing machined parts

Retrofitting of the robotics part of a nine-colour printing line