Casos particulos
04 September 2023
Troubleshooting of an induced draught fan
Client expectation
Our client is a waste reclamation and processing centre. They contacted us following an outbreak of fire on a bearing of the 450 kW electric cooling fan, causing a site shutdown.
DV GROUP Solution
Emergency intervention by the Electro-mechanical teams that same night.
When our experts arrived onsite, it appeared that the bearing had welded itself to the shaft. The decision was therefore made to displace the bearing housing in order to be able to carry out an emergency repair. Three teams from Cambrai and Grigny were required day and night in order to complete the work.
The client restarted production the next evening.
In order to secure production, we put in place continuous machine feedback.
Work carried out
- Machine monitoring using a Phantom captor for feedback following the work
- Replacement of bearing housings, onsite modification of the chassis in order to displace the housing fixing
Experiencia
Le ofrecemos soluciones de ingeniería, mantenimiento y control basadas en nuestro conocimiento de sus procesos.
Casos prácticos
También le puede interesar

Repair and reliability of drives
Casos prácticos
12 September 2023

ELOPAK: Corrective preventive electronic maintenance
Casos prácticos
12 September 2023

Preventive maintenance of Siemens Masterdrives
Casos prácticos
11 September 2023

43 Simovert Masterdrive drives from 0.75 kW to 700 kW
Casos prácticos
11 September 2023

To safeguard the reliability of 32 Siemens (6SE70) Masterdrives on a paper machine section
Casos prácticos
11 September 2023

MELEGHY: Preventive maintenance of 24 Siemens Powerblocks drives
Casos prácticos
11 September 2023

Preventive maintenance contract
Casos prácticos
05 September 2023

Emergency repair on a 120KW ABB ACS800 drive
Casos prácticos
05 September 2023

2 LEROY SOMER 600 kW variators
Casos prácticos
05 September 2023

Overhaul of 12 Siemens Torque Simotics T-1FW3 motors
Casos prácticos
05 September 2023

Preventive maintenance for 17 Siemens servomotors and drives
Casos prácticos
04 September 2023

X-FAB : Replacement of two extractor fans
Casos prácticos
04 September 2023

19 50 kg (2.2 kW) to 5 ton (7.2MW) motor/reducer/ventilator assemblies
Casos prácticos
01 September 2023

Overhaul of an extruder reducer with 2 indexed output shafts
Casos prácticos
01 September 2023

LENGLET IMPRIMEURS : 1€ to reduce your energy bill
Casos prácticos
01 September 2023

Modelling of the HTA/BT electric network
Casos prácticos
01 September 2023

Motorisation of compressors in a colliery gas compression station
Casos prácticos
29 August 2023

Obsolescence of the oven’s 7 CC ALSTHOM drives
Casos prácticos
29 August 2023

Retrofitting of an impressive balancing bench
Casos prácticos
29 August 2023

Retrofit of a machine for superfinishing machined parts
Casos prácticos
29 August 2023

Retrofitting of the robotics part of a nine-colour printing line
Casos prácticos
29 August 2023

Modification of the ride “Tonnerre 2 Zeus” [Zeus’ Thunder]
Casos prácticos
23 August 2023